Adaptec ICP5045BL Guida Utente

Navigare online o scaricare Guida Utente per Controller per unità periferiche Adaptec ICP5045BL. Adaptec ICP5045BL User`s guide [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 135
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti

Sommario

Pagina 1 - User’s Guide

SAS, SATA, and SCSI RAID Controllers Installation and User’s Guide

Pagina 2 - Disclaimer

Contents ● 10ACU Error Codes... 100Sample Scripts...

Pagina 3 - ICP vortex Customer Support

Appendix D: Using the Array Configuration Utility for DOS ● 100ControllerID KeywordControllerID is an optional keyword to change the SCSI ID of the co

Pagina 4

Appendix D: Using the Array Configuration Utility for DOS ● 101Sample ScriptsThis command invokes the ACU and creates arrays on controller 1 based on

Pagina 5 - Canadian Compliance Statement

Appendix D: Using the Array Configuration Utility for DOS ● 102# Clear the array (don’t build/verify it)Method=Clear# Don’t wait for clear to complete

Pagina 6 - Contents

EUsing the ICP Flash UtilityIn this appendix...System Requirements ...

Pagina 7

Appendix E: Using the ICP Flash Utility ● 104System Requirements● MS–DOS version 5.0 or later. Note: You can’t run the IFU from a DOS command prompt w

Pagina 8

Appendix E: Using the ICP Flash Utility ● 105Creating the Firmware Floppy DisksNote: You will need at least two bootable MS-DOS floppy disks to comple

Pagina 9

Appendix E: Using the ICP Flash Utility ● 1066 Complete the flash operation and restart your computer before trying to use the RAID controller again.

Pagina 10 - Technical Specifications

Appendix E: Using the ICP Flash Utility ● 107These switches are available:● /C <Controller ID>—One or more RAID controller IDs representing the

Pagina 11 - About This Guide

Appendix E: Using the ICP Flash Utility ● 108VerifyCompares the contents of each of the flash components on a RAID controller to the corresponding ima

Pagina 12 - How to Find More Information

Appendix E: Using the ICP Flash Utility ● 109Updating the Flash Using the IFU Command Line1 Create the firmware floppy disks (see page 105).2 Power of

Pagina 13 - Requirements

1About This GuideIn this chapter...What You Need to Know Before You Begin... 12

Pagina 14 - Kit Contents

FICP Serial Controller LED and I2C Connector Reference In this appendix...ICP9047MA Activity LED and I2C Connector Specification...

Pagina 15 - About Your RAID Controller

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 111ICP9047MA Activity LED and I2C Connector Specification● ICP9047MA LED Board Con

Pagina 16 - Array-level Features

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 112ICP9087MA Activity LED and I2C Connector Specification● ICP9087MA LED Board Con

Pagina 17 - RAID Controller Battery Model

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 113J14:ICP5805BL LED and I2C Connector Specification● ICP5805BL LED Board Connecto

Pagina 18 - About the ICP5805BL

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 114J10:● ICP5045BL Aggregate Activity LED Board Connector: Molex 22-28-8022 2.54mm

Pagina 19 - About the ICP5045BL

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 115ICP5085BL LED and I2C Connector Specification● ICP5085BL LED Board Connector: M

Pagina 20 - About the ICP5085BL

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 116● LED Mating Cable Connector: Molex 50-57-9002 or equivalentJ12:● ICP5085BL I2C

Pagina 21 - About the ICP5125BR

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 117SFF-8087 Connector J5:ICP5125BR LED and I2C Connector Specification● ICP5125BR

Pagina 22 - About the ICP5165BR

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 118J17: ● ICP5125BR Aggregate Activity LED Board Connector: Molex 22-28-8022 2.54m

Pagina 23 - About the ICP9085LI

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 119J7:The following pins are tied to Sideband Signals of SFF-8087 connector J3 (Po

Pagina 24 - About the ICP5085BR

Chapter 1: About This Guide ● 12What You Need to Know Before You BeginYou should be familiar with computer hardware, data storage, RAID technology, an

Pagina 25 - About the ICP9047MA

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 120SFF-8087 Connector J5:SFF-8087 Connector J18:ICP5165BR LED and I2C Connector Sp

Pagina 26 - About the ICP9087MA

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 121● ICP5165BR LED Board Connector: Molex 10-89-7162 2.54mm 2x8 Header or equivale

Pagina 27 - About the ICP9014RO

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 122● LED Mating Cable Connector: Molex 50-57-9002 or equivalentJ12:● ICP5165BR Agg

Pagina 28 - About the ICP9024RO

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 123● ICP5165BR I2C Board Connector: Molex 22-43-6030 or equivalent● I2C Mating Cab

Pagina 29 - Getting Started

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 124SFF-8087 Connector J18:SFF-8087 Connector J14:ICP9085LI LED and I2C Connector S

Pagina 30 - Choosing a RAID Level

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 125J10:Note: Board circuitry supports COMMON ANODE backplane implementations● ICP9

Pagina 31 - Selecting Disk Drives

Appendix F: ICP Serial Controller LED and I2C Connector Reference ● 126● LED Mating Cable Connector: Molex 22-552101 or equivalentJ10:Note: Board circ

Pagina 32 - Selecting Cables

GSafety InformationTo ensure your personal safety and the safety of your equipment:● Keep your work area and the computer clean and clear of debris. ●

Pagina 33 - SATA Cables

HTechnical SpecificationsIn this appendix...Environmental Specifications...

Pagina 34 - Basic Installation Steps

Appendix H: Technical Specifications ● 129Environmental SpecificationsNote: With a Battery Backup Unit (BBU), the ambient temperature should not excee

Pagina 35

2Kit Contents and System RequirementsIn this chapter...Kit Contents...

Pagina 36 - In this chapter

IndexAACUarrays 43creating arrays 43, 84creating bootable arrays 85initializing disk drives 85managing arrays 85rescanning disk drives 85secure erasin

Pagina 37 - Installing the Controller

Index ● 131command line utility 61connectors 71, 90contents of controller kit 14Controller SCSI Channel ID setting 89Controller SCSI Channel Terminati

Pagina 38

Index ● 132Ffailed disk drives 64multiple arrays 65multiple disk drives 66RAID 0 arrays 65without hot spare 65firmware 104creating floppy disks 105fir

Pagina 39

Index ● 133QQAS setting 89RRAID 16, 17non-redundant arrays 75RAID 0 75RAID 1 76RAID 10 77RAID 1E 16, 76RAID 5 78RAID 50 80RAID 5EE 16, 79RAID 6 17, 81

Pagina 40

Index ● 134SCSISelect 86secure erasing disk drives 86stopping a secure erase 86-Select utilities 86applying changes 86exiting 86modifying controller s

Pagina 41 - Connecting External Devices

ICP vortex Computersysteme GmbHKonrad-Zuse-Str.974172 NeckarsulmGermany©2007 Adaptec, Inc.All rights reserved. Adaptec and the Adaptec logo are tradem

Pagina 42 - Creating a Bootable Array

Chapter 2: Kit Contents and System Requirements ● 14Kit Contents● ICP RAID controller● RAID Installation CD (bootable), including controller drivers,

Pagina 43 - Creating an Array

3About Your RAID ControllerIn this chapter...About the ICP5805BL ...

Pagina 44

Chapter 3: About Your RAID Controller ● 16Standard RAID Controller Features● Flash ROM for updates to controller firmware, BIOS, and the ICP RAID Conf

Pagina 45

Chapter 3: About Your RAID Controller ● 17● Dual Drive Failure Protection (RAID 6)—A RAID 6 array is similar to a RAID 5 array except that it includes

Pagina 46 - Making Your Array Bootable

Chapter 3: About Your RAID Controller ● 18About the ICP5805BLThe ICP5805BL is a SAS RAID controller with these features:Form Factor Low-profile MD2Bus

Pagina 47 - Operating System

Chapter 3: About Your RAID Controller ● 19About the ICP5045BLThe ICP5045BL is a SAS RAID controller with these features:Form Factor Low-profile MD2Bus

Pagina 48 - Creating a Driver Disk

● 2Copyright©2005-2007 ICP vortex. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in

Pagina 49 - Installing with Red Hat Linux

Chapter 3: About Your RAID Controller ● 20About the ICP5085BLThe ICP5085BL is a SAS RAID controller with these features:Form Factor Low-profile MD2Bus

Pagina 50 - Installing with NetWare

Chapter 3: About Your RAID Controller ● 21About the ICP5125BRThe ICP5125BR is a SAS RAID controller with these features:Form Factor Half-size Bus comp

Pagina 51 - Installing with Solaris

Chapter 3: About Your RAID Controller ● 22About the ICP5165BRThe ICP5165BR is a SAS RAID controller with these features:Form Factor Half-size Bus comp

Pagina 52 - Installing with VMware

Chapter 3: About Your RAID Controller ● 23About the ICP9085LIThe ICP9085LI is a SAS RAID controller with these features:Form factor 3/4 lengthBus comp

Pagina 53 - Installing with FreeBSD

Chapter 3: About Your RAID Controller ● 24About the ICP5085BRThe ICP5085BR is a SAS RAID controller with these features:Form Factor 3/4 lengthBus Comp

Pagina 54

Chapter 3: About Your RAID Controller ● 25About the ICP9047MAThe ICP9047MA is a SATA II RAID controller with these features:Note: A low-profile bracke

Pagina 55

Chapter 3: About Your RAID Controller ● 26About the ICP9087MAThe ICP9087MA is a SATA II RAID controller with these features:Note: A low-profile bracke

Pagina 56 - Installing on NetWare

Chapter 3: About Your RAID Controller ● 27About the ICP9014ROThe ICP9014RO is a low-profile SCSI controller with these features: Form Factor Low-profi

Pagina 57 - Installing on Solaris

Chapter 3: About Your RAID Controller ● 28About the ICP9024ROThe ICP9024RO is a low-profile SCSI controller with these features:Form Factor Low-profil

Pagina 58 - Installing on VMware

4Getting StartedIn this chapter...Choosing a RAID Level...

Pagina 59 - Installing on FreeBSD

● 3ICP vortex Customer SupportIf you have questions about installing or using your ICP product, check this document and the Readme files on the CD fir

Pagina 60 - Managing Your Storage Space

Chapter 4: Getting Started ● 30Choosing a RAID LevelThis section provides a brief overview of the RAID levels supported by your ICP RAID controller, i

Pagina 61 - About ICP Storage Manager

Chapter 4: Getting Started ● 31Selecting Disk DrivesWhen selecting disk drives for your RAID array, ensure that all the disk drives have the same perf

Pagina 62 - Which Utility Should I Use?

Chapter 4: Getting Started ● 32Selecting CablesThis section describes the cable options and requirements for your ICP controller:● For SAS cables, see

Pagina 63 - Solving Problems

Chapter 4: Getting Started ● 33Cable connectors are keyed so that you can’t insert them incorrectly. ICP recommends using only high quality SAS cables

Pagina 64 - Silencing the Alarm

Chapter 4: Getting Started ● 34All SATA straight connector to straight connector cables have the same connectors, as shown in the following figure, an

Pagina 65

Chapter 4: Getting Started ● 353 Create a bootable array (see page 43).4 Install your operating system and the controller driver (see page 47.)5 Insta

Pagina 66 - Resetting the Controller

5Installing the Controller and Disk DrivesIn this chapter...Before You Begin ...

Pagina 67 - ) Web site at www.scsita.org

Chapter 5: Installing the Controller and Disk Drives ● 37Before You Begin● Read Safety Information on page 127.● Familiarize yourself with your ICP RA

Pagina 68 - What is SAS?

Chapter 5: Installing the Controller and Disk Drives ● 38● For SAS RAID controllers, see page 38.● For SATA RAID controllers, see page 40.● For SCSI R

Pagina 69 - What’s a Phy?

Chapter 5: Installing the Controller and Disk Drives ● 392 Use internal SAS or mini-SAS cables to attach the disk drives to the controller. 3 When al

Pagina 70 - What do SAS Cables Look Like?

● 4Limited 3-Year Hardware Warranty1. ICP vortex (“ICP”) warrants to the purchaser of this product that it will be free from defects in material and w

Pagina 71 - Backplane Connections

Chapter 5: Installing the Controller and Disk Drives ● 403 When all internal disk drives have been installed and connected, close your computer cabine

Pagina 72 - SAS Expander Connections

Chapter 5: Installing the Controller and Disk Drives ● 412 Install a terminator (or enable termination) on the disk drive at the end of each cable, or

Pagina 73

6Creating a Bootable ArrayIn this chapter...Setting the Boot Controller...

Pagina 74 - Understanding RAID

Chapter 6: Creating a Bootable Array ● 43Setting the Boot ControllerNote: If your system won’t contain more than one bootable controller, skip to the

Pagina 75 - Non-redundant Arrays (RAID 0)

Chapter 6: Creating a Bootable Array ● 444 Select Initialize Drives, then press Enter. 5 Select at least three disk drives for the array, press Insert

Pagina 76 - RAID 1 Enhanced Arrays

Chapter 6: Creating a Bootable Array ● 45Creating an Array with ICP Storage ManagerThis section describes how to use the ICP Storage Manager configura

Pagina 77 - RAID 10 Arrays

Chapter 6: Creating a Bootable Array ● 467 Review the information that is displayed.Note: In DAS environments, ICP Storage Manager uses the term logic

Pagina 78 - RAID 5 Arrays

7Installing the Driver and an Operating SystemIn this chapter...Before You Begin ...

Pagina 79 - RAID 5EE Arrays

Chapter 7: Installing the Driver and an Operating System ● 48Before You Begin● Install and connect your ICP RAID controller and internal disk drives (

Pagina 80 - RAID 50 Arrays

Chapter 7: Installing the Driver and an Operating System ● 49● For VMware, see page 52.● For FreeBSD, see page 53.Installing with WindowsNote: You wil

Pagina 81 - RAID 60 Arrays

● 5Regulatory Compliance StatementsFederal Communications Commission Radio Frequency Interference StatementWARNING: Changes or modifications to this u

Pagina 82 - Selecting the Best RAID Level

Chapter 7: Installing the Driver and an Operating System ● 50Installing with SUSE LinuxTo install the ICP RAID controller driver while installing SUSE

Pagina 83

Chapter 7: Installing the Driver and an Operating System ● 518 From the lower window menu, select Continue, then press Enter.If the driver installatio

Pagina 84 - Creating a New Array

Chapter 7: Installing the Driver and an Operating System ● 52Installing with UnixWareNote: You will need your UnixWare Installation CD to complete thi

Pagina 85 - Rescanning Disk Drives

Chapter 7: Installing the Driver and an Operating System ● 53Installing with FreeBSDNote: You will need your FreeBSD Installation CD to complete this

Pagina 86 - Applying Changes and Exiting

8Installing the Driver on an Existing Operating SystemIn this chapter...Before You Begin ...

Pagina 87 - General Controller Settings

Chapter 8: Installing the Driver on an Existing Operating System ● 55Before You BeginBefore you begin, install and connect your ICP RAID controller an

Pagina 88 - Option Description

Chapter 8: Installing the Driver on an Existing Operating System ● 56● For FreeBSD, see page 59Installing on WindowsTo install the driver on Windows:1

Pagina 89

Chapter 8: Installing the Driver on an Existing Operating System ● 577 If aacraid.ham has already been detected, delete it.8 At the Driver Name menu,

Pagina 90 - Identifying Disk Drives

Chapter 8: Installing the Driver on an Existing Operating System ● 58Installing on UnixWareTo install the driver on UnixWare:1 Start your computer, th

Pagina 91 - Viewing the Event Log

Chapter 8: Installing the Driver on an Existing Operating System ● 59Installing on FreeBSDTo install the driver on FreeBSD:1 Start your computer.2 Ins

Pagina 92

ContentsAbout This GuideWhat You Need to Know Before You Begin ... 12Terminology Used in this Guide...

Pagina 93

9Managing Your Storage SpaceIn this chapter...About ICP Storage Manager...

Pagina 94 - Running the ACU Using Scripts

Chapter 9: Managing Your Storage Space ● 61About ICP Storage ManagerNote: Currently, ICP Storage Manager is not supported on FreeBSD. To create and ma

Pagina 95 - About Record Mode

Chapter 9: Managing Your Storage Space ● 62About the ICP RAID Configuration UtilityThe ICP RAID Configuration utility is a BIOS-based utility that you

Pagina 96 - ? Description

10Solving ProblemsIn this chapter...Troubleshooting Checklist...

Pagina 97 - InitializeAll=Yes

Chapter 10: Solving Problems ● 64Troubleshooting ChecklistIf you encounter difficulties installing or using your ICP RAID controller, check these item

Pagina 98 - ACU exits with an error

Chapter 10: Solving Problems ● 65Failed Disk Drive Protected by a Hot SpareWhen an array is protected by a hot spare, if a disk drive in that array fa

Pagina 99 - Keyword Description

Chapter 10: Solving Problems ● 66Multiple Failures in the Same ArrayExcept in RAID 6 and RAID 60 arrays (see page 74), if more than one disk drive fai

Pagina 100 - ACU Error Codes

AIntroduction to Serial Attached SCSIIn this appendix...Terminology Used in This Chapter ...

Pagina 101 - Sample Scripts

Appendix A: Introduction to Serial Attached SCSI ● 68Terminology Used in This ChapterFor convenience, SAS HBAs and SAS RAID controllers are referred t

Pagina 102

Appendix A: Introduction to Serial Attached SCSI ● 69How Do SAS Devices Communicate?SAS devices communicate with each other through links. A link is a

Pagina 103

Contents ● 7Disk Drives for SAS Controllers... 31Disk Drives for SATA Controllers ...

Pagina 104 - Before You Begin

Appendix A: Introduction to Serial Attached SCSI ● 70What’s a SAS Port?Note: Because the physical link between SAS devices is from phy to phy, rather

Pagina 105 - Running the Menu-based IFU

Appendix A: Introduction to Serial Attached SCSI ● 71How are Disk Drives Identified in SAS?In the BIOS and in the management utilities (see Identifyin

Pagina 106 - Running the

Appendix A: Introduction to Serial Attached SCSI ● 72Some backplanes support daisy-chain expansion to other backplanes. For example, you can daisy-cha

Pagina 107

Appendix A: Introduction to Serial Attached SCSI ● 73How is SAS Different from Parallel SCSI?In summary, although SAS and parallel SCSI both use the S

Pagina 108

BUnderstanding RAIDIn this appendix...Understanding Drive Segments...

Pagina 109

Appendix B: Understanding RAID ● 75Understanding Drive SegmentsA drive segment is a disk drive or portion of a disk drive that is used to create an ar

Pagina 110 - Connector Reference

Appendix B: Understanding RAID ● 76RAID 1 ArraysA RAID 1 array is built from two disk drives, where one disk drive is a mirror of the other (the same

Pagina 111 - Pin Number Signal Description

Appendix B: Understanding RAID ● 77RAID 10 ArraysA RAID 10 array is built from two or more equal-sized RAID 1 arrays. Data in a RAID 10 array is both

Pagina 112

Appendix B: Understanding RAID ● 78RAID 5 ArraysA RAID 5 array is built from a minimum of three disk drives, and uses data striping and parity data to

Pagina 113 - Pin Number

Appendix B: Understanding RAID ● 79RAID 5EE ArraysA RAID 5EE array—also known as a hot space—is similar to a RAID 5 array except that it includes a di

Pagina 114

Contents ● 8Installing the Driver on an Existing Operating SystemBefore You Begin...

Pagina 115

Appendix B: Understanding RAID ● 80RAID 50 ArraysA RAID 50 array is built from six to forty-eight disk drives configured as two or more RAID 5 arrays,

Pagina 116

Appendix B: Understanding RAID ● 81RAID 6 ArraysA RAID 6 array—also known as dual drive failure protection—is similar to a RAID 5 array because it use

Pagina 117

Appendix B: Understanding RAID ● 82Selecting the Best RAID LevelUse this table to select the RAID levels that are most appropriate for the logical dri

Pagina 118

CUsing the ICP RAID Configuration UtilityIn this appendix...Introduction to the ICP RAID Configuration Utility ...

Pagina 119

Appendix C: Using the ICP RAID Configuration Utility ● 84Introduction to the ICP RAID Configuration UtilityThe ICP RAID Configuration utility comprise

Pagina 120 - SFF-8087 Connector J18:

Appendix C: Using the ICP RAID Configuration Utility ● 85Managing Existing ArraysTo view or modify existing arrays, select Manage Arrays from the main

Pagina 121

Appendix C: Using the ICP RAID Configuration Utility ● 86Secure Erasing Disk DrivesWhen you perform a secure erase on a disk drive, all data on that d

Pagina 122

Appendix C: Using the ICP RAID Configuration Utility ● 87Modifying Your Controller’s ConfigurationNote: Default controller settings are suitable for m

Pagina 123

Appendix C: Using the ICP RAID Configuration Utility ● 88SAS-specific Controller SettingsIn addition to the general settings listed on page 87, your I

Pagina 124 - SFF-8087 Connector J14:

Appendix C: Using the ICP RAID Configuration Utility ● 89SCSI-specific Controller SettingsIn addition to the general settings listed on page 87, your

Pagina 125 - 22-552101

Contents ● 9Understanding RAIDUnderstanding Drive Segments ... 75Non-redundant Arr

Pagina 126

Appendix C: Using the ICP RAID Configuration Utility ● 90Formatting and Verifying Disk DrivesYou can use the disk utilities to low-level format or ver

Pagina 127

Appendix C: Using the ICP RAID Configuration Utility ● 91The location information of a disk drive is determined by three types of connections:● Direct

Pagina 128

DUsing the Array Configuration Utility for DOSIn this appendix...Getting Started ...

Pagina 129 - Current Requirements

Appendix D: Using the Array Configuration Utility for DOS ● 93Getting StartedNote: You need a bootable floppy disk to complete this task.The ACU for D

Pagina 130

Appendix D: Using the Array Configuration Utility for DOS ● 94Running the ACU Using ScriptsTo work in the ACU using scripts:1 Insert the ACU floppy di

Pagina 131 - Index ● 131

Appendix D: Using the Array Configuration Utility for DOS ● 95About Record ModeNote: You can also create a script file manually (see the following sec

Pagina 132 - Index ● 132

Appendix D: Using the Array Configuration Utility for DOS ● 96Array Definition Block KeywordsThe array definition block always begins with the keyword

Pagina 133 - Index ● 133

Appendix D: Using the Array Configuration Utility for DOS ● 97End KeywordEnd is a required keyword, indicating the end of the block.HotspareDrives Key

Pagina 134 - Index ● 134

Appendix D: Using the Array Configuration Utility for DOS ● 98Method KeywordMethod is an optional keyword, indicating which method to use when creatin

Pagina 135 - 74172 Neckarsulm

Appendix D: Using the Array Configuration Utility for DOS ● 99Type KeywordType is a required keyword, indicating the array type. There is no default v

Commenti su questo manuale

Nessun commento