7
Quick Reference: Array Software
Part Number: 510893-00, Rev. A
Print Spec Number: 493983-00
Current Date: 10/3/95 ECN Date: 9/26/95
5 When prompted, type y to continue, or n to cancel
the operation.
To schedule a reconstruction, see Scheduling Tasks on
page 8.
Note: If you used Hot Swap Pause to stop
SCSI bus activity, resume activity by press-
ing any key at the Administrator Utility
screen.
Reactivating an Off-line Array
An array goes off-line if the power fails or if someone
removes a second disk when one has already been
removed. To reactivate an off-line array:
1 Physically correct the problem that caused the
array to go off-line.
2 From the Main menu for the array, select
Reactivate Off-line A
rray.
3 When prompted, type y to reactivate the array, or
n to cancel the operation.
Reactivating a Spare Disk
If a disk fails in an array that has spares, a spare is
automatically activated and the failed disk is marked
Down. When you replace the failed disk with a new
disk drive at the same channel and SCSI ID, the
replacement disk becomes the new spare. To reacti-
vate the new spare:
1 From the Main menu for the array, select
Reacti
vate Spare Disk.
2 Select the spare you want to reactivate.
3 When prompted, type y to reactivate the spare, or
n to cancel the operation.
Testing a Spare Disk
To test a spare disk, use the Scheduler. Instructions
are in the next section.
Commenti su questo manuale