3-6
Adaptec RAID Installation Guide
7 When the system is restarting, a blue screen appears after the
hardware detection message. When prompted to install a
third-party driver, press F6
.
Note: You only have 5 seconds to press the F6 key during the
installation startup. A hardware detection message appears
when F6 is active. Press F6 at this time; otherwise, you must
restart the installation process to complete this procedure
correctly.
8 When prompted, insert the driver disk you created in Step 1
and select Adaptec I
2
O RAID Host Adapter Driver for
Windows 2000. Press Enter and follow the instructions
displayed.
Windows NT 4.0
The following driver installation scenarios exist for
Windows NT 4.0:
■ Installing the Driver in a New System with Only One Controller on
page 3-7
■ Installing the Driver in a New System with Other Hardware on
page 3-8
■ Upgrading the Controller in an Existing System on page 3-9
■ Changing the Driver in an Existing System on page 3-10
Caution: When adding a Zero Channel RAID (ZCR)
controller to an existing system, backup all data from
system drives prior to the installation. If the boot device is
connected to one of the onboard SCSI channels, the
operating system will need to be reinstalled after installing
the ZCR controller.
Note: If you choose the Microsoft I
2
O Operating System
Module (OSM) in place of the Adaptec driver, you cannot
use Adaptec storage management software.
!
COMBINED RAID IG.BOOK Page 6 Tuesday, September 25, 2001 5:46 PM