30 Sun Storage Common Array Manager Software 6.7.0 Release Notes • February 2011
Volume segment size, when changed, requires a new profile with a
variable number of disks
Bug 6599933 –Changing a volume to a different segment size requires that you
create a new profile with the desired segment size, create a pool using that profile,
and apply the new pool to the volume. However, if the original profile was created
using a fixed number of disks instead of a variable number of disks, an error is
returned.
Workaround –Adjust the new profile so that the number of disks is variable instead
of fixed.
Volumes not deleting from the Single Page window
Bug 6807053 –Unable to delete volumes with the Show Data in Single Page” option
from the Volume Summary page. After multiple volumes are deleted, the Volume
Summary Page still shows the same number of volumes as before.
Workaround –Use paginated view to delete volumes.
Windows “ param=value” --CLI throws exception in Modify Site
Bug 6800989 Workaround –Do not insert a space before the first quotation mark.
Windows 2008 proxy host computer name must match resolved IP
address name
Bug 6952686 Workaround –Windows 2008 computer name must match the resolved
network IP address name for the software to monitor the proxy host for JBOD
arrays. Change the computer name and then restart Windows.
Documentation Issues
2500 Series Release Notes: Simplex vs. Duplex Configurations
The Sun StorageTek 2500 Series Array Release Notes, Release 1.4 (Sun part number 820-
6247-13) document contains contradictory information on pages one and 21
concerning the StorageTek 2501 Expansion Module in simplex and duplex
configurations. The correct information is this: Only Simplex 2501 expansion
modules may be attached to a Simplex 2500 series controller tray.